To make the most of your new investment,
please READ and SAVE.
Your topside control my be Rectangular and it works identical to the
oval unit.
This optional Auxiliary Spa Side Control allows you to control the four basic functions of your spa from a convenient secondary location.
Pump Key
The Pump key is used to turn the pump on or off at selected speeds. If
the pump is a single speed pump, the Pump key is used to turn it on and
off. If the pump is a two speed pump, the first press will turn on the
pump high speed, the second press will change the pump to low speed,
the third press will turn the pump off or return to a heat or
filtration mode (see note). A built-in timer will shut the pump off 20
minutes after it has been started unless the user does so manually.
When the pump is on, the Pump On Indicator will appear above the Pump
Key. NOTE: You may not be able to turn the pump off if it has started
an internal heat or filtration cycle. This is easily identified by
observing the status of the "Heater On Indicator" or the "Filter Mode
Indicator".
Light Key
The Light key is used to turn light on or off. The first press of the
Light key will turn the light on. A second press will turn the light
off. The light will automatically turn itself off after 2 hours. When
the light is on the Light On Indicator will appear above the Light Key.
Programming
Filter Cycles
You may choose to filter your spa 1, 2, or 3 times daily as required to
maintain clean, sanitary water.
At the same time, press and release both the Pump Key and the Up Arrow
Key. The current setting for filtration cycle frequency will be
displayed.
Do nothing and the control will revert to the monitoring mode, OR,
to change the frequency, press the Up or Down Arrow Key
To save the setting, at the same time, press and release the Pump and
Up Arrow Key. The cycles will repeat every 24, 12, or 8 hours within a
24 hour period, starting from the time programmed.
It is recommended that the system is powered up at a time when the
programmed cycles do not interfere with sleeping hours.
Programming Cycle
Duration
You may choose to filter your spa 60, 120 or 180 minutes per cycle as
required to maintain clean, sanitary water.
At the same time, press and release both the Light Key and the Up Arrow
Key. The current setting for filtration cycle duration will be
displayed (60,120,180).
Do nothing and the control will revert to the monitoring mode, OR,
to change the frequency, press the Up or Down Arrow Key.
To save the setting, at the same time, press and release the Light Key
and Up Arrow Key.
Important Notes
(1) If a program change is not made within 5 seconds, the system will
default back to the monitoring mode.
(2) While programming, the Pump and Light features may have been
activated. Either can be turned off in the normal way after programming
is complete.
The display will return to indicate water temperature 5 seconds after
the keys are released.
Temperature Set
Keys
The Up/Down Temperature Set Keys are used to set the desired water
temperature. Press the Up or Down keys to increase (or decrease) the
desired temperature setting. The temperature can be adjusted in
1ºF increments from 41ºF to 104ºF (or 5ºC to
40ºC.). The desired temperature setting will remain in the display
for 5 seconds as confirmation of the new value, after 5 seconds the
display will return to display the present water temperature.
Heater Operation
When the water temperature drops 1ºF lower than the desired
temperature, the heater will be turned on until the water temperature
reaches the desired temperature plus 1ºF. The Heater On Indicator
will appear on the function panel when it is on. The Heater On Light
Indicator will blink on the function panel whenever there is a call for
heat and the heater has not yet been powered.
Freeze Protection
If the water temperature falls below 40ºF, the system will start a
special process to circulate the water in the pipes. Pump and heater
will be turned on for one minute. The message FrE will be
displayed throughout the special cycle. During this cycle all other
functions of the unit (except the alarms) are disabled.
High Temperature
Protection
If the water temperature exceeds 115ºF at the High Temperature
probe, the system will display the message HL and will turn the
heater off. If the water temperature exceeds 122ºF at the High
Temperature probe, the high limit circuit will turn off all outputs. In
either case, after the water temperature has cooled down, pressing any
key on the spaside panel control will restart the system.
If the spa water temperature does not seem to be elevated, the HL
reading may have been caused by poor water flow or electrical line
interference (e.g. thunderstorms, voltage surges, etc.). Simply reset
and monitor the system.
NOTE: After the unit cools down below 115ºF, the
Freeze Protection Circuit can automatically engage if needed.
System Error
Indicators
FLC-Flow Related Problem**
FLO-Flow Related Problem**
PrH-High Temperature Probe Problem**
Prr-Temperature Probe Problem**
HL-High Temperature Protection*
FrE-Freeze Protection Mode Engaged*
You may also experience "three flashing
dots"
These also indicate an error. **
* See Section Above
** Contact Your Local Dealer for Service
Default System
Operations
When power is applied, or there is a temporary loss of power, the
system will initiate its default programming. The filter cycle starts
24 hours after the system has been powered up, filters one hour, and
then repeats every 24 hours. The maintained temperature will default to
95ºF. The freeze protection feature will stay in effect.